Parameters & concepts
TR, TE, bandwidth, matrix and the other parameters: what each one changes, and the core concepts behind them. 24 free pages.
Parameters and their trade-offs
TR (repetition time) in MRI: what it changes
TR sets T1 weighting and most of the scan time. This is what happens to the image and the clock when you move it.
TE (echo time) in MRI: what it changes
TE sets T2 weighting. A longer TE gives more T2 contrast and less signal.
TI (inversion time) in MRI: STIR, FLAIR and nulling a tissue
TI decides which tissue is switched off. The right value depends on the tissue and on the field strength.
Flip angle in MRI: what it does to contrast and SAR
The flip angle controls T1 weighting in gradient echo and drives SAR in spin echo. This is how to choose it.
ETL and turbo factor in MRI: speed against blurring
A longer echo train shortens the scan and blurs the image. This is where the limit is.
Receiver bandwidth in MRI: SNR against chemical shift and metal
A narrow bandwidth gives more signal and more chemical shift. A wide one does the opposite and helps near metal.
FOV in MRI: resolution, SNR and wrap
A smaller FOV gives finer detail, less signal and a risk of aliasing. This is how to balance it.
Matrix size in MRI: resolution against time and SNR
More matrix means smaller pixels, a longer scan and less signal per pixel.
Slice thickness and gap in MRI
Thin slices show small structures and lose signal. The gap controls cross-talk and coverage.
NEX, NSA and averages in MRI: what doubling really buys
Doubling the averages doubles the time and gives only 41% more SNR. This is when it is worth it.
Phase-encoding direction in MRI: how to choose it
The phase direction decides where motion ghosts and wrap appear. Choose it so they miss the anatomy you need.
Parallel imaging factor (ASSET, SENSE, GRAPPA): how far to push it
Acceleration shortens the scan and costs SNR. The coil decides how high you can go.
Partial Fourier (half scan) in MRI
Part of k-space is skipped and filled in by calculation. It saves time or shortens TE, at a cost.
Fat suppression methods in MRI: fat sat, SPAIR, STIR and Dixon
Four ways to make fat dark. Each one fails in a different situation, so the choice depends on the anatomy.
b-value in DWI: how to choose it
A higher b-value gives more diffusion weighting and less signal. The right value depends on the organ.
Saturation bands in MRI: where to put them
A sat band removes signal from tissue that would send ghosts into the image. This is where it helps and what it costs.
1.5 T versus 3 T MRI: what changes for the technologist
3 T gives more signal and brings more SAR, more susceptibility and different T1 values. This is what to adjust.
Concepts in plain words
Why MRI ghosts follow the phase-encoding direction
Motion and pulsation ghosts spread along the phase direction. Knowing why tells you where to send them.
k-space explained for MRI technologists
k-space is where the scanner collects the image data. A few facts about it explain scan time, contrast timing and several artifacts.
MRI weighting explained: which of TR and TE does what
T1, T2 and PD weighting come from two settings. This is the short version to keep in your head at the console.
Inversion recovery explained: how STIR and FLAIR switch a tissue off
An inversion pulse and a waiting time remove the signal of one tissue. That is all STIR and FLAIR are.
Fat and water frequency difference in MRI
Fat and water resonate at slightly different frequencies. Fat sat, chemical shift and Dixon all come from this one fact.
Parallel imaging explained for technologists
The coil elements supply position information, so the scanner can skip lines of k-space. This is what it costs.
SNR, resolution and scan time: the trade-off in every MRI protocol
You can improve two of the three and the third pays for it. Every protocol change is a move inside this triangle.